Svisd-ITB
Control unit for the security access control to restricted areas through 2 or more interlocking doors.
It is configurable for the management of monobloc interlocking (not weighed) passages, formed by standard door wings equipped with electric locks or motorised door wings (sliding doors etc).
It controls the locking/unlocking of interlocking wings, the human presence sensors between the doors inside the booth, the traffic lights and push-button panels on the door wings, the command console, all anomaly (door not closed, user not leaving the area etc) and alarm (emergency alarm and biometric controller alarm) conditions that may occur during the transit in the area delimited by the interlocking wings.
Many types of transit through interlocking doors have been created: bi-directonal, one-way entrance, one-way exit, manual, emergency, lock etc.
Also configurable for any electric lock or motorized models (pistons, rotating strike plates, NO, NC, sliding doors etc).
Fully equipped with vocal (vocal synth system and pre-recorded messages) and optical (LCD display and signalling LEDs) interface for those who transit between the interlocking doors and for the operator who work on the command console.
Proprietary software, which ca be personalized on the customer’s request.
- Microcontroller card with watch-dog, RAM Time-keeper (8k), serial RS 232/RS 485;
- Optoisolated inputs (n.24);
- Outputs with relays (n.5);
- Outputs with transistors (n.19);
- Programmable speech synthesis (on-board);
- Specific software (possible integration on request);
- Power supply 12 Vdc;
- IP20 aluminium case.